See figure, F.35, Troubleshooting and repair – Lincoln Electric VRTEXTM 360 SVM200-A User Manual
Page 135

FIGURE F.35 – SHORTCUT TO START-UP SIM SCREEN SHOT
INTERFACE MODULE DIGITAL (USB)
REMOVAL AND REPLACEMENT PROCEDURE (continued)
11. Click on the following in order:
• Start
• All Programs
• National Instruments
• Measurement and Automation
See Figure F.36
• Devices and Interfaces (click “+”)
• USB Devices
• Tools
• NI-Visa
• Visa Options
• Aliases
• Clear all Aliases
• OK
• Close out Screen
• YES (to save)
12. At this point, a basic computer screen desktop
will appear.
13. Click on the following in order:
• Start
• All Programs
• National Instruments
• Measurement and Automation
• Devices and Interfaces (click “+”)
• USB Devices (click “+”)
• USB 0……………….
14. In the box labeled “Visa Alias” on my system,
type these letters: LECSPI (in CAPS)
15. Save and close out screen.
16. Shut down the VRTEX
TM
360 via a normal CPU
shutdown. Click:
• Start
• Turn off computer
• Turn off
17. Remove input power after CPU has complete-
ly shut down.
18. Disconnect the USB keyboard and mouse.
19. Perform Case Cover Replacement
20. Perform the Monitor and Pedestal
21. See Retest After Repair.
TROUBLESHOOTING AND REPAIR
F-78
F-78
VRTEX
TM
360