139

11.

Highlight

C

ALIBRATE

and press

ENT

. The following message will ap-

pear: Full Level Calibration Completed. Press

ENT

, then press

EXIT

re-

peatedly to get back to the main display.

Num Pts menu with 5-point calibration selected (left). Half level se-

lected on Fluid Level menu (center). Calibration Done window (right).

5-Point Calibration

5-point calibration is best suited tanks that vary greatly in shape from

top to bottom. You can begin calibration at any point in the 5-point

calibration process. We recommend starting calibration with an empty

tank. In a five-point calibration you will set five points: Empty Level, 1

Qtr Level, Half Level, 3 Qtr Level and Full Level. In a 5-point calibra-

tion, you will have four calibration points left after calibrating your

tank's Empty Level.
To figure out how much fuel you should add for the remaining steps of

the calibration process, divide the total capacity of you tank by four. So,

if you have a 40-gallon tank, each quarter tank will equate to 10 gal-

lons.
1. Press

MENU| MENU

, use

↓ ↑ to select

NMEA

2000

and press

ENT

.

2. Highlight

B

US

S

ETUP

and press

ENT

, which will open the Bus Configu-

ration menu. A list of network devices will be at the top of the page. 3.

Select the desired EP-15 Fluid Level and press

ENT

.

4. Press

↓ to select

C

ALIBRATE

and press

ENT

. The Device Calibration

menu will appear.
5. Highlight

N

UM

P

TS

, press

ENT

and select

5

. Press

ENT

.

6.

Make sure your tank is empty, then

highlight

F

LUID

L

EVEL

and press

ENT

.

Select

E

MPTY LEVEL

and press

ENT.

7.

Select

C

ALIBRATE

and press

ENT

. The following message will appear:

Empty Level Calibration Completed. Press

ENT

.

8.

Add 1 quarter tank of fuel, highlight

F

LUID

L

EVEL

and press

ENT

.

Select

1

Q

TR

L

EVEL

and press

ENT.