TROUBLESHOOTING GUIDE
SYMPTOM
PROBABLE CAUSE
CORRECTIVE ACTION
Key pad malfunction.
Run Key pad test in diagnostics.
Replace if defective.
TV Channels do not change.
Interface PC board defective.
Replace Interface PC board.
Key pad malfunction.
Run Key pad test in diagnostics.
Replace if defective.
TV Sound does not change.
Interface PC board defective.
Replace Interface PC board.
Faulty headphones.
Replace headphones.
Faulty headphone jack assembly.
Replace headphone jack assembly.
Faulty cable to Headphone jack
assembly
Replace Headphone jack cable.
No TV sound.
Air/cable setting may not be correct
Follow the set up procedures in the
operator manual.
Air/cable setting may not be correct.
Follow the setup procedures in the
operator manual.
Coax Cable may be bad.
Replace Coax Cable.
Unable to receive any TV
channels when using cable.
Coax Cable may be unplugged
Reconnect Cable.
Air/cable setting may not be correct.
Follow the setup procedures in the
operator manual.
Snow and noise appear on
the screen.
Coax cable may be bad.
Replace Coax cable.
LCD Back Light burned up.
Replace LCD/Touch Screen.
Back Light power inverter bad
Replace backlight inverter
LCD Screen failure
Replace LCD/Touch Screen.
Screen is blank
Problem on the single board computer
Replace Single Board Computer.
LCD Back Light burned up.
Replace LCD/Touch Screen.
Screen is dark.
Back Light power inverter bad
Replace backlight inverter
Touch screen failure.
Replace LCD/Touch Screen.
Screen Does not respond to
touch.
Problem with Single Board Computer.
Replace Single Board Computer.
Touch Screen not calibrated correctly
Calibrate Touch Screen in Diagnostics.
The wrong buttons activate
when the touch screen is
touched.
Touch Screen Damaged.
Replace LCD/Touch Screen.
No power.
Check Wax/lift board for 12 & 5 volts
DC and replace if faulty.
Screen does not turn ON and
no sound.
Faulty wire harness to console.
Replace Wire Harness
Back light inverter defective.
Replace inverter.
Console does not Light up but
there are audible Beeps
LCD defective.
Replace LCD\TOUCH screen