Life Fitness 93T User Manual
Page 145
3-30
Plunger
Orientation
Stop
Switch
Plastic
Nut
Switch Body
Plunger
Orientation
Bezel
Explode Side View
Stop Switch
in Body
Plungers MUST Be
Properly Orientated
Bezel
Assembled View
Life Fitness Model 97Te, 95Te, 97Ti, 95Ti and 93T Arctic Silver Treadmills
How To... Replace the STOP Button/Switch
Special Service Tools Required: NONE
5. Insert the Stop Button Switch through the opening in the
front of the Bezel Assembly, and orient the Switch Body
so the work “STOP” is readable from the face of the
Bezel.
6. Install the Plastic Nut on to the threaded portion of the
Switch Body with the flat side toward the back of the
Bezel and tighten1/8 of a turn past hand tight. Do Not
over tighten the Plastic Nut.
CAUTION: Over tightening the Plastic Nut may cause
damage to the Switch Body or Bezel.
7. Insert the Stop Switch into the STOP Button/Switch, and take
special note to orient the two parts so the Switch Plungers
make contact upon assembly.
Note: Verify that the plungers are making contact by pressing the
STOP Button and visually ensuring they make contact with each
other.
8. Reconnect the wiring being careful not to bend or break the
connecting tabs.
9. Refer to Diagnostics Section to Log Maintenance Repair of
the Stop Switch.