beautypg.com

Retest after repair, Troubleshooting and repair – Lincoln Electric EAGLE SVM192-A User Manual

Page 88

background image

TROUBLESHOOTING AND REPAIR

F-52

F-52

EAGLE™ 10,000

RETEST AFTER REPAIR

Retest a machine:

• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the

machine’s electrical characteristics.

OR

• If you repair or replace any electrical components.

ENGINE OUTPUT

Mode

No Load RPM

Load RPM

Low Idle

2150-2250

NA

High Idle

3700-3750

3100-3600

WELDER DC OUTPUT

1

Output Control

Range Switch

Open Circuit

Load Volts

Load Amps

Volts

Maximum

Maximum

65 - 72

21 - 26.5

205 - 240

AUXILIARY POWER RECEPTACLE OUTPUT

1

230 Volt Receptacle

115 Volt Receptacle

2

Open Circuit

Load Volts

Load Amps

Open Circuit

Load Volts

Load Amps

Voltage

Voltage

246 - 264

216 - 250

34 - 41.5

123- 132

114 - 126

35 - 42

FIELD AMPS AND VOLTS

Slip Ring Volts

Field Amps

28.0 - 46.0 VDC

6.5 - 7.5 VDC

1

OUTPUT CONTROL switch set at MAXIMUM (position 10).

2

Output values of each receptacle can vary within the range shown but must be within 2 volts of each other.