INSTALLATION

A-7

A-7

EAGLE™ 10,000

120 V DUPLEX RECEPTACLES

The 120V auxiliary power receptacles should only be

used with three wire grounded type plugs or approved

double insulated tools with two wire plugs.

The current rating of any plug used with the system

must be at least equal to the current load through the

associated receptacle.

MOTOR STARTING

Most 1.5 hp AC single phase motors can be started if

there is no load on the motor or other load connected

to the machine, since the full load current rating of a

1.5 hp motor is approximately 20 amperes (10

amperes for 240 volt motors). The motor may be run at

full load when plugged into only one side of the duplex

receptacle. Larger motors through 2 hp can be run pro-

vided the receptacle rating as previously stated is not

exceeded. This may necessitate 240V operation only.

GND

120 V

120 V*

240 V

*Current Sensing for Automatic Idle.

(Receptacle viewed from front of Machine)

EAGLE 10,000 Extension Cord Length Recommendations

(Use the shortest length extension cord possible sized per the following table.)

Current

(Amps)

15

20

15

20

38

Voltage

Volts

120

120

240

240

240

Load

(Watts)

1800

2400

3600

4800

9000

30

60

(9)

(18)

40

30

75

60

(12)

(9)

(23)

(18)

75

50

150

100

50

(23)

(15)

(46)

(30)

(15)

125

88

225

175

90

(38)

(27)

(69)

(53)

(27)

175

138

350

275

150

(53)

(42)

(107)

(84)

(46)

300

225

600

450

225

(91)

(69)

(183)

(137)

(69)

Maximum Allowable Cord Length in ft. (m) for Conductor Size

Conductor size is based on maximum 2.0% voltage drop.

14 AWG

12 AWG

10 AWG

8 AWG

6 AWG

4 AWG

AUXILIARY POWER

The EAGLE 10,000 can provide up to 9,000 watts of

120/240 volts AC, single phase 60Hz power for contin-

uous use, and up to 10,000 watts of 120/240 volts AC,

single phase 60Hz power peak use. The front of the

machine includes three receptacles for connecting the

AC power plugs; one 50 amp 120/240 volt NEMA 14-

50R receptacle and two 20 amp 120 volt NEMA 5-20R

receptacles. Output voltage is within +/-10% at all

loads up to rated capacity. See

Table I for more infor-

mation.

Do not connect any plugs that connect to the

power receptacles in parallel.

------------------------------------------------------------------------

Start the engine and set the “IDLER” control switch to

the desired operating mode. Set the “CONTROL” to

10. Voltage is now correct at the receptacles for auxil-

iary power.

120/240 VOLT DUAL VOLTAGE RECEPTACLE

The 120/240 volt receptacle can supply up to 38 amps

of 240 volt power to a two wire circuit, up to 38 amps

of 120 volts power from each side of a three wire cir-

cuit (up to 76 amps total). Do not connect the 120 volt

circuits in parallel. Current sensing for the automatic

idle feature is only in one leg of the three wire circuit as

shown in the following column.

CAUTION

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC