OUTPUT PROBLEMS

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,

contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.

Call 1-888-935-3877.

CAUTION

No auxiliary power, welding output

is normal. Engine runs normally.

1. If machine is equipped with cir-

cuit

breakers,

check

circuit

breakers CB1 thru CB5. Reset if

tripped.

2. Make sure the Output Control

(R1) is set at the maximum posi-

tion.

3. Check for loose or faulty plug(s)

at the power receptacle(s).

1. Check

the

auxiliary

power

receptacles

and

associated

wires for loose or faulty connec-

tions.

2. Perform

the

Auxiliary and

Field Winding Voltage Test.

3. If machine is equipped with cir-

cuit breakers, check for faulty

breakers and loose or faulty

connections

on

associated

wiring.