beautypg.com

Troubleshooting and repair, Caution – Lincoln Electric EAGLE SVM192-A User Manual

Page 44

background image

ENGINE PROBLEMS

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,

contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.

Call 1-888-935-3877.

CAUTION

Engine will not idle down to low

speed. Machine has normal weld

output and auxiliary power.

1. Make sure the Idler Switch (S4)

is in the “Auto” position.

2. Make sure there is NOT an exter-

nal load on the weld terminals

nor the auxiliary power recepta-

cles.

1. With the Idler Switch (S4) in the

“Auto” position, check for the

presence of 12VDC at leads

#213 to #215 located at the

Idler Solenoid. If 12VDC is pre-

sent and the Idler Solenoid is

not activating, then the solenoid

may be faulty or there is a

mechanical restriction prevent-

ing it from functioning.

2. If there is NOT 12VDC at leads

#213 to #215, then test for

12VDC

from

lead

#213

to

ground (lead #5).

See

Wiring

Diagram. If 12VDC is present,
then check lead #215 for conti-

nuity (zero ohms) from the Idler

Solenoid to the Printed Circuit

Board plug 3J1. If lead #215 is

OK, then the Printed Circuit

Board may be faulty. Replace.

3. If there is NOT 12VDC from

lead #213 to ground (lead #5),

then check the Idler Switch (S4)

for proper operation and as-

sociated wires for loose or faulty

connections.

TROUBLESHOOTING AND REPAIR

F-8

F-8

EAGLE™ 10,000

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC