Kenwood RC-D710 User Manual
Page 35

PACKET-
Command Name
Short
Description
Parameter
Default
KISS
KISS
When ON, entering a RESTART command causes the
TNC to enter (or exit) KISS mode.
ON/ OFF
OFF
LCSTREAM
LCS
When ON, changes a small letter (a through z) entered
as a stream designator, to a capital letter (A through
Z). A stream designator must be entered immediately
after STREAMSW.
ON/ OFF
ON
LIST
LI
Displays the list of messages, in the TNC mailbox,
other than those addressed to other stations.
−
−
LOCATION
LOC
If set to EVERY, sends GPS data at intervals of the
specified period (n). If set to AFTER, sends GPS data
only once after the specified period (n). The unit of n
is 10 seconds.
EVERY/ AFTER
n
(n = 0 ~ 250)
EVERY 0
LOG
LOG
Displays the list of stations which have connected to
the TNC mailbox.
−
−
LPATH
LPA
Specifies call signs to send GPS data. Call1 is the call
sign of the destination. Call2 to call9 are call signs of
stations to be digipeated through.
Call1 (VIA call2,
call3, ... call9)
GPS
LTEXT
LT
Specifies the content of a message to be included in
GPS data.
0 ~ 159
characters
−
LTMON
LTM
Specifies the interval for displaying a message
determined by LTEXT on the screen; a message
appears like a received beacon packet. The unit of the
parameter is 1 second.
0 ~ 250
0
MAI
When ON and the TNC mailbox holds a message
addressed to you, outputs “Low” to the MAILLED
terminal.
ON/ OFF
OFF
MAXFRAME
MAX
Specifies the maximum number of packets to be
transmitted at one time.
1 ~ 7
4
MBOD
MB
When ON, allows the TNC mailbox to be used.
ON/ OFF
OFF
MCOM
MCOM
When ON, causes the TNC to also monitor control
packets. When OFF, causes it to monitor only
information packets.
ON/ OFF
OFF
MCON
MC
When ON, causes the TNC to monitor other stations
while in connection with the target station.
ON/ OFF
OFF
MINE
MI
Displays the list of messages, in the TNC mailbox,
addressed to you and messages that you sent.
−
−
MONITOR
M
When ON, causes the TNC to monitor packets.
ON/ OFF
ON
MRPT
MR
When ON, causes the TNC to display the entire
digipeat list for monitored packets.
ON/ OFF
ON
MSTAMP
MS
When ON, causes the TNC to display data and time
information for monitored packets.
ON/ OFF
OFF
MYALIAS
MYA
Specifies a call sign for using your station as a
digipeater.
6 characters +
SSID
−
MYCALL
MY
Specifies your call sign.
6 characters +
SSID
−
MYMCALL
MYM
Specifies a call sign to be assigned to your TNC
mailbox.
6 characters +
SSID
−
NEWMODE
NE
When ON, entering a CONNECT command causes
the TNC to immediately enter the other mode.
ON/ OFF
OFF
NOMODE
NO
When ON, does not cause the TNC to automatically
enter the other mode. When OFF, causes it to
automatically enter the other mode as specified by
NEWMODE.
ON/ OFF