Validating the Scanner
May 2002
3-7
3. Use the table below only as a starting point for determining Scan Area
values.
NOTE: Keep the Line Offset (y): at the default value of 0 and keep Pixel
Summing at the default value of None.
IMPORTANT: The Pixel Offset must be greater than or equal to the first
calibrated pixel and # Pixels must be less than or equal to the
last calibrated pixel minus the first calibrated pixel.
Cut-Gate Film
Holders
Magnification
# Pixels
Pixel Offset
# Lines
File Size
(MB)
35 mm double-
perforated
0.50
1033
2484
1460
4.3
1.03
2129
1936
3008
18.3
2.00
4133
934
5840
69.1
46 mm
0.50
1754
2123
2554
12.8
0.60
2105
1948
3065
18.5
1.58
5542
229
8071
128.0
6 x 4.5 cm
vertical
0.50
2368
1816
1539
10.4
0.66
3126
1437
2031
18.2
1.26
5967
17
3878
66.2
6 x 4.5 cm
horizontal
0.50
1539
2231
2368
10.4
0.66
2031
1985
3126
18.2
1.26
3878
1061
5967
66.2
6 x 6 cm
0.50
2368
1816
2250
15.2
0.55
2605
1698
2475
18.5
1.26
5967
17
5670
96.8
6 x 7 cm
0.50
2368
1816
2775
18.8
1.26
5967
17
6994
119.4
6 x 9 cm
0.50
2368
1816
3325
22.5
1.19
5636
182
7914
127.6
Split 70 mm
0.50
2483
1759
1632
11.6
0.63
3129
1436
2056
18.4
1.20
5960
20
3917
66.8
70 mm
0.50
2682
1659
3450
26.5
1.09
5846
77
7522
125.8
4 x 5 in.
0.50
3972
1014
5026
57.1
0.74
5878
61
7439
125.1
max mag
2.00
6000
0
7333
125.9
min mag
0.50
2917
1542
3750
31.3