Calibrating the pedals, Alibrating, Pedals – KORG STAGE VINTAGE SV-1 User Manual

Page 45

background image

Advanced settings | Calibrating the pedals – 31

English

C

ALIBRATING

THE

PEDALS

You can calibrate the pedals connected to the DAMPER, PEDAL 1 and PEDAL 2
connectors in the back panel. By calibrating a pedal, you let the SV-1 understand
its polarity and the full range of values sent.

1.

Connect all pedals to be calibrated to the SV-1. Remember that DAMPER
expects the included Korg DS-2H damper pedal, PEDAL 1 expect a foots-
witch-type pedal, and PEDAL 2 can be used to connect either a footswitch or
expression-type pedal.

2.

Set any expression-type pedal to its lowest setting.

3.

Turn the SV-1 off.

4.

Keep the AUTO/PEDAL button pressed, and turn the SV-1 on.

5.

When the AUTO/PEDAL LED starts to flash, release the button.

If you do nothing in the next few seconds, the AUTO/PEDAL LED will turn
off, and the SV-1 will complete the start-up sequence.

6.

While the AUTO/PEDAL LED is flashing, press the button again. SV-1 enters
calibration mode.

7.

Now calibrate PEDAL 1 (a footswitch). Completely depress the pedal, then
release it. When you have finished calibrating the pedal connected to the
PEDAL 1 jack, FAVORITE button #1 will turn on.

8.

Then, calibrate PEDAL 2. The procedure is different, depending on the use of
a footswitch or an expression pedal:

• If you connected a footswitch, completely depress it, then release it.

• If you connected an expression pedal, push it all the way forward to its max-
imum position, then return the pedal to its minimum or lowest position.

When you have finished calibrating the pedal connected to the PEDAL 2 jack,
FAVORITE button #2 will turn on.

9.

Finally calibrate the DAMPER pedal. Completely depress the pedal, then
release it. When you have finished calibrating the pedal connected to the
DAMPER jack, FAVORITE button #3 will turn on.

10.

When finished calibrating:

• If you calibrated all three pedals connected, SV-1 automatically exits cali-
bration mode and continue the start-up sequence.

• If you calibrated only one or two pedals, press the AUTO/PEDAL button
again to exit calibration mode and continue the start-up sequence.