beautypg.com

Kodak Scanners i800 Series User Manual

Page 45

background image

5-2

A-61169 July 2003

Cleaning the upper
transport area

Follow the steps below to clean the upper transport area:

1. Open the top cover.

2. Open the bi-fold door.

3. Grasp the end of the lower imaging guide and slowly pull it straight out.

4. Place the lower imaging guide on a clean surface.

5. Grasp the end of the upper imaging guide and slowly pull it straight out.