STEP 18A

MAIN GAS VALVE CHECK

SBD 120 – 400 GAS VALVE



STEP 18A. MAIN GAS VALVE CHECK.
Disconnect wires from gas valve TH and TR
terminals. Using a multimeter, test for 68 ohms plus or minus 5 between TH and TR on
the main valve coil.

IF THEN
The meter reads ‘O’ or infinity

Replace the gas valve

The meter reads 68* ohms plus or minus 5

The main burner will ignite


TH

TR