beautypg.com

State Industries SBD85 500 User Manual

Page 34

background image

SBD TANK TYPE HEATERS

SERVICE HANDBOOK

Technical Training Department

Ashland City, TN ©2003

33

STEP 13

PILOT SPARK TEST

STEP 13. PILOT SPARK TEST. Visually check for spark at the pilot assembly.
Note: The pilot burner mounts on the left side of the main burner.

IF THEN
The igniter is not sparking:

Check for:

A 7/64” spark gap

Spark cable continuity

Ground cable continuity

Sparking is present:

Go to step 14.




Power To Module May Be Interrupted To Reset .

Trial for Ignition

90 sec.

5 min.

90 sec.

5 min.

90 sec.


Call for
heat


Sparking


No
Sparking


Sparking


No
Sparking


Sparking

Continuous
Trial
Sequence




This manual is related to the following products: