Electrical requirements – Sub-Zero 427R User Manual
Page 6

Models 424 and 424FS Installation
6
Electrical Requirements
For models 424 and 424FS, the electrical supply should
be located within the shaded area shown in the illustra-
tion. Follow the National Electrical Code and local codes
and ordinances when installing the receptacle. A separate
circuit, servicing only this appliance is required. A ground
fault circuit interrupter (GFCI) is not recommended and
may cause interruption of operation.
IMPORTANT NOTE:
For model 424, the electrical outlet
must be placed so the grounding prong is to the right of
the thinner blades. The outlet must be flush with the back
wall.
Do not use an extension cord or two-prong adapter.
Electrical ground is required on this appliance. Do not
remove the power cord ground prong.
Electrical Requirements
Power Supply
115 V AC, 60 Hz
Circuit Breaker
15 amp
Receptacle
3-prong grounding-type
FRONT VIEW
15
1
/
2
"
(394)
3"
(76)
2"
(51)
Location of electrical supply.
The outlet must be checked by a qualified electrician to
be sure that it is wired with the correct polarity and is
properly grounded.