Parallel output on command, Projector power control command – Sony RS-232C User Manual
Page 11
– 11 –
PARALLEL OUTPUT ON: 43[H] 50[H] 4F[H] 4E[H] (‘CPON’)
This command is used to turn on OUTPUT of the REMOTE PARALLEL terminals separately of the SRP-X700P.
•
Packet format
43[H] 50[H] 4F[H] 4E[H] “parameter” 0D[H]
•
Parameter
Same as that of the PARALLEL OUT OFF command.
Example: When turning on channel 1
43[H] 50[H] 4F[H] 4E[H] 31[H] 0D[H] (‘C P O N 1 CR’)
PROJECTOR POWER CONTROL: 43[H] 50[H] 4A[H] 50[H] (‘CPJP’)
This command is used to turn on the power or to set the power standby of the projected that is connected to the PROJECTOR CONTROL
terminal of the SRP-X700P.
•
Packet format
43[H] 50[H] 4A[H] 50[H] “parameter” 0D[H]
•
Parameter
Specify either POWER ON or POWER STANDBY as the parameter.
Example: When turning on the power of projector
43[H] 50[H] 4A[H] 50[H]41[H] 0D[H] (‘C P J P A CR’)
POWER
STANDBY
40[H] ( ‘@’ )
ON
41[H] ( ‘A’ )
- AWS-G500E (12 pages)
- XDCAM (28 pages)
- OXF-R3 (396 pages)
- MDM-X4 (194 pages)
- DMX-P01 (49 pages)
- SRP-X500P (37 pages)
- SRP-X500P (43 pages)
- XBA-H1 (2 pages)
- CPF-NW001 (100 pages)
- MDS-JE500 (37 pages)
- MDR-SA1000 (2 pages)
- MDR-SA1000 (2 pages)
- MDR-EX15AP (2 pages)
- ICD-TX50 (2 pages)
- MDR-KX70LW (2 pages)
- HAR-D1000 (20 pages)
- HAR-D1000 (52 pages)
- HAR-D1000 (108 pages)
- SA-NS400 (2 pages)
- NAS-SV20i (11 pages)
- SA-NS300 (2 pages)
- SA-NS300 (40 pages)
- SRS-A201 (2 pages)
- ICD-SX1000 (2 pages)
- ICD-SX1000 (2 pages)
- NWZ-B173 (2 pages)
- ICF-C763 (2 pages)
- ICF-C763 (2 pages)
- SRS-M30 (2 pages)
- TDM-NC1 (483 pages)
- TDM-NC1 (2 pages)
- TDM-NC1 (467 pages)
- ICF-CD855L (2 pages)
- CFD-E10 (2 pages)
- ICD-B600 (2 pages)
- MHC-ZX10 (60 pages)
- NWZ-Z1040 (2 pages)
- NWZ-Z1040 (2 pages)
- DR-EX12iP (2 pages)
- HAP-S1 (213 pages)
- HAP-Z1ES (59 pages)
- MDR-XB400 (1 page)
- XBA-4 (2 pages)
- RDP-X200IPN (2 pages)