beautypg.com

Attaching the slide-rail assemblies to the rack – Sun Microsystems Sun Fire X4100 M2 User Manual

Page 13

background image

Chapter 1

Setting Up the Server Hardware

5

Attaching the Slide-Rail Assemblies to the Rack

Use this procedure to install the slide-rail assemblies to the rack.

1. Position a slide-rail assembly in your rack so that the brackets at each end of the

slide-rail assembly are on the outside of the front and rear rack posts. See

FIGURE 1-3

.

2. Attach the slide-rail assembly to the rack posts.

The method used to attach the slide-rails varies depending on the type of rack:

If your rack has threaded mounting holes in the rack posts, first determine
whether the threads are metric or standard, then insert the correct mounting
screws through the slide-rail brackets and into the threaded holes.

If your rack does not have threaded mounting holes, insert the mounting screws
through both the slide-rail brackets and rack posts, then secure them with the
caged nuts.

FIGURE 1-3

Slide-Rail Assembly Mounting to Rack Post

3. Repeat the procedure for the remaining slide rail assembly.

Slide-rail

assembly
with mounting

bracket removed

Rack post

Slide-rail assembly

bracket on outside
of rack post