Installing the mounting brackets onto the server – Sun Microsystems Sun Fire X4100 M2 User Manual
Page 12
4
Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007
Installing the Mounting Brackets Onto the Server
Use this procedure to install the mounting brackets onto the sides of the server.
1. Position a mounting bracket against the chassis so that the slide-rail lock is at the
server front, and the three keyed openings on the mounting bracket are aligned
with the three locating pins on the side of the chassis. See
.
FIGURE 1-2
Aligning the Mounting Bracket With the Server Chassis
2. With the heads of the three chassis locating pins protruding though the three
keyed openings in the mounting bracket, pull the mounting bracket toward the
front of the chassis until the mounting-bracket clip locks into place with an
audible click. See
.
3. Verify that all three locating pins are trapped in the keyed openings and that the
rear locating pin has engaged the mounting-bracket clip. See
.
4. Repeat the procedure to install the remaining mounting bracket on the other side
of the server.
Chassis front
Slide-rail lock
Mounting-bracket clip
Mounting bracket