Diagnosing Power Problems with the LED Indicators
The Power and RPU LED indicators work in combination to indicate
power status as follows.
Table A-2 Power/RPU LED Indicators
Power and Cooling Problems
If the power indicator does not turn on when the power cord is plugged in,
you may have a problem with the power outlet, power cord, or internal
power supply. However, if the unit powers off after running for a while,
check for loose power connections, power losses or surges at the power
outlet, and verify that the fans on the unit are unobstructed and running
prior to shutdown. If you still cannot isolate the problem, the internal
power supply may be defective.
Power LED RPU LED Status
Green
Green
Internal power functioning normally; RPU is
present.
Green
Amber
Internal power functioning normally; RPU plugged
in but faulty.
Green
Off
Internal power functioning normally; RPU not
plugged in.
Amber
Green
Internal power faulty; RPU delivering power.
Off
Off
Both internal power and RPU unplugged or not
functioning.