Mounting, Rack mounting – SMC Networks SMC TigerStack III SMC6826MPE User Manual

Page 44

background image

I

NSTALLING

THE

S

WITCH

3-4

Mounting

This switch can be mounted in a standard 19-inch equipment rack or on a
desktop or shelf. Mounting instructions for each type of site follow.

Rack Mounting

Before rack mounting the switch, pay particular attention to the following
factors:

Temperature: Since the temperature within a rack assembly may be
higher than the ambient room temperature, check that the
rack-environment temperature is within the specified operating
temperature range. (See page C-2.)

Mechanical Loading: Do not place any equipment on top of a
rack-mounted unit.

Circuit Overloading: Be sure that the supply circuit to the rack
assembly is not overloaded.

Grounding: Rack-mounted equipment should be properly grounded.
Particular attention should be given to supply connections other than
direct connections to the mains.

To rack-mount devices:

1. Attach the brackets to the device using the screws provided in the

Bracket Mounting Kit.