At-200ge – JAI AT-200GE User Manual
Page 56

AT-200GE
- 54 -
Specifications
AT-200GE
Functions controlled via GigE
Vision Interface
Shutter, gain, black level, trigger mode, read out mode,
GPIO setup, ROI (GenICam mandatory functions)
GigE Vision Streaming Control
Packet size, delayed (frame) read-out, inter-packet delay
Jumbo frame can be set at max. 16K (16020) , default packet size is 1476 Byte.
Operating temperature
-5
C to +45
C.
Humidity
20 - 80% non-condensing
Storage temp./humidity
-25
C to 60
C./20% - 80 % non-condensing
Vibration
3 G (15 Hz – 200 Hz in XYZ)
Shock
50 G
Regulations
CE (EN 61000-6-2, EN 61000-6-3), FCC part 15 class B, RoHS
Power
10.8V to 26.4V DC. 0.61 A (Typical , Full frame ,12V input)
0.68 A (Typical ,1/8 partial, +12V input)
Lens mount
C-mount (Rear protrusion on C mount must be less than 4mm)
The lens used should be designed for 3CCD cameras.
Flange back
17.526mm, Tolerance +0 to –0.05mm
Optical axis
Center
0.1mm
Dimensions
55 x 55 x 98.3 mm (HxWxD)
Weight
320g
Note 1: Partial scan and vertical binning can not be used at the same time. Partial scan has a priority.
Note 2: Above specifications are subject to change without notice
Note 3:
Specifications are valid after a 30 min. warm up period.