beautypg.com

7 vertical timing (vertical binnin, Operating modes - timing, 1 continuous operation – JAI AT-200GE User Manual

Page 42: At-200ge

background image

AT-200GE

- 40 -

9.6.7 Vertical timing (vertical binning mode)


Fig.40 Vertical timing for V binning.

9.7. Operating Modes - Timing

9.7.1 Continuous operation
For applications not requiring asynchronous external triggering, this mode should be used. In
this mode it possible to use a lens with a video controlled iris.
For timing details, refer to fig.35. through fig.40.

To use this mode:
Set function:

Exposure mode

Continuous

Pixel format

RGB8, 10V1, 10V2

Partial scan

Fast dump ON, ROI

Vertical binning

Binning vertical ON

Shutter mode

Programmable, Exposure Time Abs,

Auto shutter








1 2 3 4 5

DVAL

Ef f ec t i v e L i nes

1L

4 L

0 . 5 L

L V A L

F V A L

EEN

S G

S UB

L VAL

FVAL

1 FVAL Per i od

XEEN

(Hi rose 12pi n)

6 1 8 L

6 2 6 L

6 2 6 L

5 L

O B

6

1

8

▪ 1L=1LVAL period (57.54μs)

▪ OB=Optical black

Exposure

period

DATA out

2L

Res

er

ev

ed

Res

er

ev

ed

2L