7 vertical timing (vertical binnin, Operating modes - timing, 1 continuous operation – JAI AT-200GE User Manual
Page 42: At-200ge

AT-200GE
- 40 -
9.6.7 Vertical timing (vertical binning mode)
Fig.40 Vertical timing for V binning.
9.7. Operating Modes - Timing
9.7.1 Continuous operation
For applications not requiring asynchronous external triggering, this mode should be used. In
this mode it possible to use a lens with a video controlled iris.
For timing details, refer to fig.35. through fig.40.
To use this mode:
Set function:
Exposure mode
Continuous
Pixel format
RGB8, 10V1, 10V2
Partial scan
Fast dump ON, ROI
Vertical binning
Binning vertical ON
Shutter mode
Programmable, Exposure Time Abs,
Auto shutter
1 2 3 4 5
DVAL
Ef f ec t i v e L i nes
1L
4 L
0 . 5 L
L V A L
F V A L
EEN
S G
S UB
L VAL
FVAL
1 FVAL Per i od
XEEN
(Hi rose 12pi n)
6 1 8 L
6 2 6 L
6 2 6 L
5 L
O B
6
1
8
▪ 1L=1LVAL period (57.54μs)
▪ OB=Optical black
Exposure
period
DATA out
2L
Res
er
ev
ed
Res
er
ev
ed
2L