Configuring the Chassis Alarm
NetScreen-5000 Series
31
For example, if you assigned the MGT interface an IP address of
10.100.2.183
/16, then enter:
http://10.100.2.183
The NetScreen WebUI software displays the login prompt.
3.
Enter netscreen in both the Admin Name and Password fields, and then
click Login. (Use lowercase letters only. The Admin Name and Password fields
are both case sensitive.)
The NetScreen WebUI application window appears.
C
ONFIGURING
THE
C
HASSIS
A
LARM
The NetScreen-5000 Series system allows you to configure the chassis alarm, an audible
warning that sounds when a system failure or hazardous event occurs. To determine
which failures and events trigger the chassis alarm:
1.
Configure the audible alarms by executing the following command:
set chassis audible-alarm string
where string can be any of the following keywords:
2.
After configuring the alarm, it is advisable to view alarm environment
information by executing the following command:
get chassis
all
Enables all chassis alarms.
battery
Sets the chassis alarm to sound when a battery fails.
fan-failed
Sets the chassis alarm to sound when a fan fails.
power-failed
Sets the chassis alarm to sound when a power supply fails.
temperature
Sets the chassis alarm to sound when the temperature goes outside of
the acceptable range.