Fan modules, Netscreen-5000 modules, 5000 m – Juniper Networks 5000 User Manual
Page 13: Odules, Creen

Fan Modules
NetScreen-5000 Series
5
F
AN
M
ODULES
The NetScreen-5200 has a three-fan module and the NetScreen-5400 has a two-fan
module. You can access the fan module from the left front side of each chassis.
•
To remove the NetScreen-5200 fan module, turn the fan knob in the unlock
position, then gently pull the fan module lever toward you to slide the module
out.
•
To remove the NetScreen-5400 fan module, loosen the two thumb screws that
secure the fan module, then gently slide the module out.
If a fan stops operating due to failure or removal, then the system continues to run and
generates an alarm. When you replace the fan, do not leave the fan tray empty for more
than two minutes. See
“Replacing the Fan Module” on page 37
for more information.
N
ET
S
CREEN
-5000 M
ODULES
The NetScreen-5000 Series systems support two module types:
•
NetScreen-5000 management modules
•
NetScreen-5000 Secure Port Modules (SPMs)
The following table shows the modules supported by each slot.
The following table shows the configurations for each Management Modules and Secure
Port Module and shows if the firmware version is included on the Management Module or
needs to be downloaded.
slot 1
slot 2
slot 3
slot 4
NetScreen-5200
Management
Module
Secure Port
Module
N/A
N/A
NetScreen-5400
Management
Module
Secure Port
Module
Secure Port
Module
Secure Port
Module
Configuration 1
Configuration 2
Configuration 3
Management Module
5000-MGT
5000-MGT2
5000-MGT2
Secure Port Module
5000-8G and/or
5000-2G24FE
5000-8G and/or
5000-2G24FE
5000-8G2 and/or
5000-2XGE
Software Version
Software is installed on
the shipping
management module.
Software is installed on
the shipping
management module
Must download from the
support site.
www.juniper.net/
support