Chapter 3 Configuring the Device

30

User’s Guide

For example, if the MGT interface has an address of

10.100.2.183

, then enter:

telnet

10.100.2.183

3.

At the Username prompt, type your user name (default is netscreen).

4.

At the Password prompt, type your password (default is netscreen).

5.

(Optional) By default, the console times out and terminates automatically after
10 minutes of idle time. To change this timeout interval, execute the following
command:

set console timeout number

where number is the length of idle time in minutes before session termination.
To prevent any automatic termination, specify a value of 0.

Starting a Console Session Using Dialup

Each NetScreen-5000 Series system provides a modem port that allows you to establish a
remote console session using a dialup connection through a 9600 bps modem. Dialing into
the modem establishes a dialup console connection.

Establishing a GUI Management Session

To access a NetScreen-5000 Series system with the WebUI management application:

1.

Connect your computer (or your LAN hub) to the MGT interface using a
Category-5 Ethernet cable. (The MGT interface is on the 5000-M or 5000-M2
management modules, which always reside in slot 1.)

2.

Launch your browser, enter the IP address of the MGT interface in the URL
field, and then press Enter.

Note:

Use lowercase letters only. Both username and password are case-sensitive.

Note:

The Terminal type for dialup sessions must be vt100. For example, in Hilgreave

HyperTerminal (a commonly-used terminal application), select the File menu. select
Properties, select the Settings tab, and then under the Emulation drop-down menu,