Interphase Tech iSPAN 5535 PRI User Manual
Page 116

Understanding LoopTest Messages
96
Interphase Corporation
Test failed
The connection between the two ISDN B channels 
could not be established before time-out because 
another application answered the call. The Remote 
Access Server was probably running when the test 
started. To restart the test:
1. From the Start menu, select Programs, then
Administrative Tools (Common), and then 
Remote Access Admin. 
2. From the Server menu, select Stop Remote Access
Service.
3. Launch LoopTest again as described in Testing your
ERROR: The 
pattern does not 
arrive on the 
other end
OR
ERROR: A bad 
pattern has been 
received: frame 
When the connection is established, the test sends a 
pattern on one B channel, and should receive it on the 
other B channel. This message occurs when the pattern 
is lost or invalid. Possible causes are:
• The test application might be connected to another
application.
• The ISDN number might be wrong.
• An incoming call from another application arrived
and was answered by LoopTest.
• The line or the network is defective.
Test aborted
This message is displayed with an ISDN standard 
clearing cause.
The corrective actions depend on the displayed cause. 
(For example, check your ISDN number if No user 
response or Incomplete Address messages appear).
Other messages
You canceled the test in progress by clicking Stop.
Message
Cause