beautypg.com

Intel Express 5800/120Ld User Manual

Page 139

background image

Problem Solving 5-17

Table 5-2. Post Error Beep Codes

Beeps

Error

Cause

Recommended Action

1-2-2-3

ROM Checksum Error

Change system board

1-3-1-1

DRAM Refresh Test Error

Change memory DIMM's

1-3-1-3

Keyboard Controller Test Error

Change system board

1-3-3-1

Memory Not Detected

No memory.

Can not write to memory

Verify DIMM installation.

Change memory DIMM's

Memory Capacity Check Error

No memory.

Can not write to memory

Verify DIMM installation.

Change memory DIMM's

1-3-4-1

DRAM Address Test Error

Memory address signal failure

Change DIMM or M/B

1-3-4-3

DRAM Test low byte Error

Memory data signal failure (low)

Change DIMM or M/B

1-4-1-1

DRAM Test high byte Error

Memory data signal failure (high)

Change DIMM or M/B

1-4-3-3

All Memory Group Errors

2-1-2-3

BIOS ROM Copy-Write Test Error

Error with Shadow RAM

Change system board

2-2-3-1

Unexpected Interrupt Test Error

Unexpected interrupt

Change CPU or system
board

2-3-1-3

All Memory Group Errors

Memory address signal failure

Change DIMM or M/B

3-3-1-4

Memory Not Detected

1-2

Option ROM Initialization Error

Failure to initialize Option ROM
BIOS

Change system board or
option board

1-2

Video configuration fails

Failure to initialize VGA BIOS

Change option video board
or system board

1-2

OPTION ROM Checksum Error

Failure to initialize Option BIOS

Change M/B or option board