Intel Express 5800/120Ld User Manual
Page 137
Problem Solving 5-15
Table 5-1. Post Error Codes and messages (Continued)
Code
Error Message
0B33
Power Unit Fan 1 Alarm occurred
0B34
Power Unit Fan 2 Alarm occurred
0B46
ESMINT not configured
0B50
CPU #1 with error taken off line
0B51
CPU #2 with error taken off line
0B5F
Forced to use CPU with error
0B60
DIMM group #1 has been disabled
0B61
DIMM group #2 has been disabled
0B62
DIMM group #3 has been disabled
0B63
DIMM group #4 has been disabled
0B6F
DIMM group with error is enabled
0B70
The error occurred during temperature sensor reading
0B71
System Temperature out of range
0B74
The error occurred during voltage sensor reading
0B75
System Voltage out of range
0B7C
The error occurred during fan sensor reading
0B80
BMC Memory Test Failed
0B81
BMC Firmware Code Area CRC check failed
0B82
BMC core hardware failure
0B83
BMC IBF or OBF check failed
0B90
BMC Platform Information Area Corrupted
0B91
BMC update firmware corrupted
0B92
Internal Use Area of BMC FRU corrupted
0B93
BMC SDR Repository empty
0B94
IPMB signal lines do not respond
0B95
BMC FRU device failure
0B96
BMC SDR Repository failure
0B97
BMC SEL device failure
0BB0
SMBIOS - SROM data read error
0BB1
SMBIOS - SROM data checksum bad
0BD0
1
st
SMBus device address not acknowledged
0BD1
1
st
SMBus device Error detected
0BD2
1
st
SMBus timeout