beautypg.com

Intel Express 5800/120Ld User Manual

Page 137

background image

Problem Solving 5-15

Table 5-1. Post Error Codes and messages (Continued)

Code

Error Message

0B33

Power Unit Fan 1 Alarm occurred

0B34

Power Unit Fan 2 Alarm occurred

0B46

ESMINT not configured

0B50

CPU #1 with error taken off line

0B51

CPU #2 with error taken off line

0B5F

Forced to use CPU with error

0B60

DIMM group #1 has been disabled

0B61

DIMM group #2 has been disabled

0B62

DIMM group #3 has been disabled

0B63

DIMM group #4 has been disabled

0B6F

DIMM group with error is enabled

0B70

The error occurred during temperature sensor reading

0B71

System Temperature out of range

0B74

The error occurred during voltage sensor reading

0B75

System Voltage out of range

0B7C

The error occurred during fan sensor reading

0B80

BMC Memory Test Failed

0B81

BMC Firmware Code Area CRC check failed

0B82

BMC core hardware failure

0B83

BMC IBF or OBF check failed

0B90

BMC Platform Information Area Corrupted

0B91

BMC update firmware corrupted

0B92

Internal Use Area of BMC FRU corrupted

0B93

BMC SDR Repository empty

0B94

IPMB signal lines do not respond

0B95

BMC FRU device failure

0B96

BMC SDR Repository failure

0B97

BMC SEL device failure

0BB0

SMBIOS - SROM data read error

0BB1

SMBIOS - SROM data checksum bad

0BD0

1

st

SMBus device address not acknowledged

0BD1

1

st

SMBus device Error detected

0BD2

1

st

SMBus timeout