90
Hardware Maintenance Manual: xSeries 200
015-XXX-198
(USB device connected
during USB test)
1.
Remove USB devices from USB1 and USB2
2.
Re-run test
3.
System Board
020-XXX-000
(Failed PCI Interface test)
1.
System Board
030-XXX-000
(Failed Internal SCSI interface
test)
1.
System Board
030-XXX-00N
(Failed SCSI test on PCI slot
N. Check system error log
before replacing a FRU.)
1.
Adapter in Slot N
035-XXX-099
1.
No adapters were found.
2.
If adapter is installed re-check connection.
035-XXX-S99
(Failed RAID test on PCI slot
S. S = number of failing PCI
slot. Check System Error Log
before replacing a FRU.)
1.
Adapter
2.
SCSI Backplane
3.
Cable
035-XXX-SNN
(Check System Error Log
before replacing a FRU. S =
number of failing PCI slot;
NN = SCSI ID of failing fixed
disk.)
1.
Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S.
035-253-S99
(RAID adapter initialization
failure)
1.
ServeRAID Adapter in slot S is not configured properly.
Obtain the basic and
extended configuration status and refer to the ServeRAID Hardware Maintenance
Manual for more information.
2.
Cable
3.
Adapter
075-XXX-000
(Failed Power Supply test)
1.
Power Supply
089-XXX-001
(Failed Microprocessor test)
1.
Microprocessor
180-XXX-003
(Failed System Board LED
test)
1.
System Board
201-XXX-0NN
(Failed Memory test, see
"Memory Settings" on page
31.) NN = DIMM location.
1.
DIMM Location J1-J4
2.
Memory card
Error Code/Symptom
FRU/Action