Diagnostic error codes – IBM x Series 200 User Manual

Page 97

background image

Symptom-to-FRU index

89

Diagnostic error codes

Note:

In the following error codes, if XXX is 000, 195, or 197,do not replace a FRU.
The description for these error codes are:

000

The test passed.

195

The

Esc

key was pressed to abort the test.

197

This is a warning error and may not indicate a hardware failure.

For all error codes, replace/follow the FRU/Action indicated.

No ac power

1.

Check the power cord.

2.

Power supply.

No beep and no video

1.

See “Undetermined problems” on page 100

Error Code/Symptom

FRU/Action

001-XXX-000

(Failed core tests)

1.

System Board

001-XXX-001

(Failed core tests)

1.

System Board

001-250-000

(Failed System Board ECC)

1.

System Board

001-250-001

(Failed System Board ECC)

1.

System Board

005-XXX-000

(Failed Video test)

1.

Video Adapter (if installed)

2.

System Board

011-XXX-000

(Failed COM1 Serial Port test)

1.

System Board

011-XXX-001

(Failed COM2 Serial Port test)

1.

System Board

014-XXX-000

(Failed Parallel Port test)

1.

System Board

015-XXX-001

(USB interface not found,
board damaged)

1.

System Board

015-XXX-015

(Failed USB External
Loopback test)

1.

Make sure parallel port is not disabled

2.

Re-run USB External Loopback test

3.

System Board

No Beep Symptom

FRU/Action