beautypg.com

Server features – IBM x Series 200 User Manual

Page 12

background image

4

Hardware Maintenance Manual: xSeries 200

Server features

The design of the 200 takes advantage of advancements in data storage and memory
management. The server combines:

Impressive performance using an innovative approach to microprocessor
utilization

The server comes with one Celeron

®

or Pentium

®

III microprocessor installed.

Table 1. Features and Specifications.

Microprocessor:

Supports one

microprocessor (depending on your
model)

Intel

®

Pentium

®

III with 256 KB

Level-2 cache and MMX™
(MMX2) technology

or

Intel

®

Celeron

®

with 128 KB

Level-2 cache and MMX™
(MMX2) technology

Memory:

Minimum: 64 MB

Maximum: 1.5 GB

Type: PC133 MHz, ECC SDRAM,
unregistered DIMMs only

Slots: 3 dual inline

Drives:

(depending on your model)

Diskette: 1.44 MB

CD-ROM: IDE

Hard disk drive

Tape drive

Expansion bays:

Two 5.25-in. bays (one CD-ROM
drive installed)

Two 3.5-in. bays (one diskette
drive installed)

Three 3.5-in. slim-high bays
available

PCI expansion slots:

Three 33 MHz/32-bit on the
system board (some models come
with a SCSI adapter installed)

Two 33 MHz/32-bit on the PCI
Bus extender board

AGP slot:

Accelerated graphics port

(AGP)

Power supply:

One 330 watt (90-240 V ac)

Video:

S3 Savage 4 AGP video adapter

Compatible with SVGA and
VGA

8 MB SDRAM video memory

Size:

Height: 470 mm (18.5 in.)

Depth: 508 mm (19.9 in.)

Width: 165 mm (6.5 in.)

Weight: approximately 19.5 Kg
(43 lb.) when fully configured or
15.9 Kg (35 lb.) minimum

Integrated functions:

10BASE-T/100BASE-TX
Ethernet controller on the
system board

Two serial ports

One parallel port

Two USB ports

Keyboard port

Mouse port

MIDI port

Audio ports

Line out

Line in

Mic

Dual-channel bus mastering
IDE controller

Acoustical noise emissions:

Sound power, idling: 6.6 bel
maximum

Sound power, operating: 6.8 bel
maximum

Environment:

Air temperature:

Server on: 10

°

to 35

°

C (50.0

°

to 95.0

°

F). Altitude: 0 to 914

m (2998.7 ft.)

Server on: 10

°

to 32

°

C (50.0

°

to 89.6

°

F). Altitude: 914 m

(2998.7 ft.) to 2133 m (6998.0
ft.)

Server off: 10

°

to 43

°

C (50.0

°

to 109.4

°

F). Maximum

altitude: 2133 m (6998.0 ft.)

Humidity:

Server on: 8% to 80%

Server off: 8% to 80%

Heat output:

Approximate heat output in British
Thermal Units (Btu) per hour

Minimum configuration: 341 Btu
(100 watts)

Maximum configuration: 1604 Btu
(470 watts)

Electrical input:

Sine-wave input (50-60 Hz)
required

Input voltage low range:

Minimum: 90 V ac

Maximum: 137 V ac

Input voltage high range:

Minimum: 180 V ac

Maximum: 265 V ac

Input kilovolt-amperes (kVA)
approximately:

Minimum: 0.08 kVA

Maximum: 0.52 kVA