beautypg.com

IBM x Series 200 User Manual

Page 103

background image

Symptom-to-FRU index

95

114

(Adapter read-only memory
error)

1.

Failing adapter

2.

Run diagnostics

129

(Internal cache error)

1.

Microprocessor

151

(Real time clock error)

1.

Run Diagnostics

2.

Battery

3.

System Board

161

(Real time clock battery error)

1.

Run Configuration/Setup

2.

Battery

3.

System Board

162

(Device Configuration Error)

Note:

Be sure to load the
default settings and
any additional
desired settings; then,
save the configura-
tion.

1.

Run Configuration/Setup

2.

Battery

3.

Failing Device

4.

System Board

163

(Real-Time Clock error)

1.

Run Configuration/Setup

2.

Battery

3.

System Board

164

(Memory configuration
changed, see "Memory
Settings" on page 31.)

1.

Run Configuration/Setup

2.

DIMM

3.

System Board

175

(Hardware error)

1.

System Board

176, 177, 178

(Security hardware error)

1.

Run Configuration/Setup

2.

System Board

184

(Power-on password
corrupted)

1.

Run Configuration/Setup

2.

System Board

185

(Drive startup sequence
information corrupted)

1.

Run Configuration/Setup

2.

System Board

186

(Security hardware control
logic failed)

1.

Run Configuration/Setup

2.

System Board

Error Code/Symptom