Ibm totalstorage san switch – IBM DR550 User Manual
Page 10

IBM System Storage DR550
Version 3.0 ------17 March 2006
Page 10
IBM Storage Systems
Copyright © 2006 by International Business Machines Corporation
provide high performance and functionality. Events such as upgrades to support the latest version of
DS4000 Storage Manager can also often be executed without stopping operations.
IBM DS4100 Storage Server in the DR550 at a glance
Characteristics
Model
1724-100
RAID controller
Dual active 2 GB RAID controllers
Cache
512 MB total, battery-backed
Host interface
4 - Fibre Channel (FC) Switched and FC Arbitrated Loop (FC-
AL) standard
Drive interface
Redundant 2 Gbps FC-AL connections
EXP100 drives
400 GB 7200 RPM SATA disk drives
EXP100 enclosures
14 400 GB SATA
disk drive modules, offering up to 5.6
Terabytes (TB) of physical capacity per enclosure
RAID
Level 5 configured. RAID-10 can be configured at the
customer’s site using an optional IBM Services consultant
Maximum drives supported
112 Serial ATA drives (using 8 EXP100 Expansion Units) per
DS4100
Fans
Dual redundant, hot-swappable
Management software
IBM DS4000 Storage Manager version 9.12.65 (Special
version for exclusive use with DR550)
IBM TotalStorage SAN Switch
Two IBM TotalStorage SAN Fibre Channel Switches are used to interconnect both P5 520 servers
with the DS4100s to create a SAN (dual node configurations). Tape attachment such as the 3592,
TS1120 or LTO can be done using the additional ports on the switches. The switches (2005-B16)
build two independent SANs, which are designed to be fully redundant for high availability. This
implementation in the DR550 is designed to provide high performance, scalability, and high fault
tolerance.
For the single node configurations, only one switch (2005-B16) included. This creates a single
independent SAN and can be used for both disk and tape access.
The 2005-B16 is a 16-port, dual speed, auto-sensing fibre channel switch. Eight ports are
populated with 2 gigabit shortwave transceivers when the DR550 is configured for single copy
mode. Twelve ports are populated with 2 gigabit short wave tranceivers when the DR550 is
configured for enhanced remote volume mirroring. This dual implementation is designed to provide
a fault tolerant fabric topology, to help avoid single points of failure.
IBM SAN Fibre Channel Switch 2005-B16
Each switch in the DR550 comes pre-zoned by ports. Both switches are configured with distinct
zones as illustrated below:
Accessing the Switch(es)
If you need to access the switch(es) to review the zoning information, error messages, or other
information, you will need to connect Ethernet cables (provided by the customer) to the Ethernet port