9 thermal data (preliminary), Thermal data (preliminary), Table 72 – Marvel Group Integrated Controller 88F6281 User Manual
Page 129

Thermal Data (Preliminary)
Copyright © 2008 Marvell
Doc. No. MV-S104859-U0 Rev. E
December 2, 2008, Preliminary
Document Classification: Proprietary Information
Page 129
9
Thermal Data (Preliminary)
provides the package thermal data for the device. This data is derived from simulations that
were run according to the JEDEC standard.
The documents listed below provide a basic understanding of thermal management of integrated
circuits (ICs) and guidelines to ensure optimal operating conditions for Marvell products. Before
designing a system it is recommended to refer to these documents:
Application Note, AN-63 Thermal Management for Selected Marvell® Products, Document
Number MV-S300281-00
White Paper, ThetaJC, ThetaJA, and Temperature Calculations, Document Number
MV-S700019-00.
Note
TET
The thermal parameters are preliminary and subject to change.
Table 72: Thermal Data for the 88F6281 in the BGA 19 x 19 mm Package (Preliminary)
S y m b o l
D e f i n i t i o n
A i r f l o w Va l u e ( C / W )
0 [ m / s ]
1 [ m / s ]
2 [ m / s ]
θ
JA
Thermal resistance: junction to ambient.
20.2
18.7
18.1
Ψ
JT
Thermal characterization parameter:
junction to case center.
7.0
7.0
7.1
θ
JC
Thermal resistance: junction to case (not air-flow dependent)
8.4
Ψ
JB
Thermal characterization parameter:
junction to the bottom of the package.
10.7
10.6
10.6
θ
JB
Thermal resistance:
junction to the bottom of the package (not air-flow dependent)
10.9