44. COLOR SYSTEM Select

Function
The external control equipment sets the COLOR SYSTEM of the plasma
monitor.

Transmission Data

DFH 80H

60H

5CH 01H

DATA00 CKS

DATA00: 01H: 3.58NTSC

02H: 4.43NTSC
03H: PAL
04H: SECAM
0AH: AUTO1
0BH: PAL60
0CH: AUTO2
0DH: PAL- M
0EH: PAL- N

ACK

7FH

60H

80H

5CH 01H

DATA00 CKS

DATA00: 01H: 3.58NTSC

02H: 4.43NTSC
03H: PAL
04H: SECAM
0AH: AUTO1
0BH: PAL60
0CH: AUTO2
0DH: PAL- M
0EH: PAL- N

45. Multi Screen Select

Function
The external control equipment selects single screen mode or multi screen
mode of the display.

Transmission Data

DFH 80H

60H

07H

01H

DATA00

CKS

DATA00: Multi Screen

00H: Single screen
01H: Side by Side1 (Same size screen)
02H: Side by Side2 (Left screen smaller)
03H: Picture in Picture sub screen L1
04H: Picture in Picture sub screen R1
05H: Side by Side3 (Left screen bigger)
06H: Picture in Picture sub screen L2
07H: Picture in Picture sub screen R2
08H: Picture in Picture sub screen L3
09H: Picture in Picture sub screen R3
0AH: Picture in Picture sub screen L4
0BH: Picture in Picture sub screen R4
10H: SWAP (The screen of the right and the left interchanges)

Side by Side

20H: Active Left
21H: Active Right

Picture in Picture

30H: Active Main
31H: Active Sub

ACK
The display returns the following ACK.

7FH

60H

80H

07H

01H

DATA00

CKS

DATA00: Multi Screen

00H: Single screen
01H: Side by Side1 (Same size screen)
02H: Side by Side2 (Left screen smaller)
03H: Picture in Picture sub screen L1
04H: Picture in Picture sub screen R1
05H: Side by Side3 (Left screen bigger)
06H: Picture in Picture sub screen L2
07H: Picture in Picture sub screen R2
08H: Picture in Picture sub screen L3
09H: Picture in Picture sub screen R3
0AH: Picture in Picture sub screen L4
0BH: Picture in Picture sub screen R4
10H: SWAP (The screen of the right and the left interchanges)

Side by Side

20H: Active Left
21H: Active Right

Picture in Picture

30H: Active Main
31H: Active Sub

When other commands (except POWER OFF) are sent while the screens
are switching with this command, the other command will be returned as