30. MENU ADJ. Gain Data

Function
The external control equipment sets the position of the OSM menu of the
plasma monitor.

Transmission Data

DFH 80H

60H

1AH

02H

DATA00 DATA01 CKS

DATA00: OSM ADJ. Gain Flag

02H

DATA01: 01H: 1

09H: 9

ACK

7FH

60H

80H

1AH

01H

DATA00 CKS

DATA00: OSM ADJ. Gain Flag

02H

31. POWER MGT Select

Function
The external control equipment switches on or off the POWER
MANAGEMENT of the plasma monitor.

Transmission Data

DFH 80H

60H

1AH

02H

DATA00 DATA01 CKS

DATA00: POWER MGT Select

03H

DATA01: 01H: ON

02H: OFF

ACK

7FH

60H

80H

1AH

02H

DATA00 DATA01 CKS

DATA00: POWER MGT Select

03H

DATA01: 01H: ON

02H: OFF

32. GRAY LEVEL Set

Function
The external control equipment sets the GRAY LEVEL of the plasma
monitor.

Transmission Data

DFH 80H

60H

C6H 01H

DATA00 CKS

DATA00: GRAY LEVEL

00H: 0

0FH: 15

ACK

7FH

60H

80H

C6H 01H

DATA00 CKS

DATA00: GRAY LEVEL

00H: 0

0FH: 15

33. CINEMA MODE Set

Function
The external control equipment switches on or off the CINEMA MODE of
the plasma monitor.

Transmission Data

DFH 80H

60H

C1H 01H

DATA00 CKS

DATA00: CINEMA MODE Set

01H: ON
02H: OFF

ACK

7FH

60H

80H

C1H 01H

DATA00 CKS

DATA00: CINEMA MODE Set

01H: ON
02H: OFF

34. LONG LIFE Set

Function
The external control equipment sets the PLE, ORBITER, and INVERSE
(inverse of image brightness) of the plasma monitor.

Transmission Data

DFH 80H

60H

6BH

03H

DATA00 DATA01 DATA02 CKS

DATA00: PLE

01H: AUTO
02H: LOCK

DATA01: INVERSE

01H: ON

02H: OFF
03H: WHITE

DATA02: ORBITER (PICTURE SHIFT)

01H: ON
02H: OFF

ACK
The plasma monitor returns the following ACK when setting the PLE,
ORBITER, and INVERSE (inverse of image brightness):

3FH

60H

80H

6BH

00H

CKS