MITSUBISHI ELECTRIC PD-5010 User Manual
Page 54
48
30. MENU ADJ. Gain Data
Function
The external control equipment sets the position of the OSM menu of the
plasma monitor.
Transmission Data
DFH 80H
60H
1AH
02H
DATA00 DATA01 CKS
DATA00: OSM ADJ. Gain Flag
02H
DATA01: 01H: 1
09H: 9
ACK
7FH
60H
80H
1AH
01H
DATA00 CKS
DATA00: OSM ADJ. Gain Flag
02H
31. POWER MGT Select
Function
The external control equipment switches on or off the POWER
MANAGEMENT of the plasma monitor.
Transmission Data
DFH 80H
60H
1AH
02H
DATA00 DATA01 CKS
DATA00: POWER MGT Select
03H
DATA01: 01H: ON
02H: OFF
ACK
7FH
60H
80H
1AH
02H
DATA00 DATA01 CKS
DATA00: POWER MGT Select
03H
DATA01: 01H: ON
02H: OFF
32. GRAY LEVEL Set
Function
The external control equipment sets the GRAY LEVEL of the plasma
monitor.
Transmission Data
DFH 80H
60H
C6H 01H
DATA00 CKS
DATA00: GRAY LEVEL
00H: 0
0FH: 15
ACK
7FH
60H
80H
C6H 01H
DATA00 CKS
DATA00: GRAY LEVEL
00H: 0
0FH: 15
33. CINEMA MODE Set
Function
The external control equipment switches on or off the CINEMA MODE of
the plasma monitor.
Transmission Data
DFH 80H
60H
C1H 01H
DATA00 CKS
DATA00: CINEMA MODE Set
01H: ON
02H: OFF
ACK
7FH
60H
80H
C1H 01H
DATA00 CKS
DATA00: CINEMA MODE Set
01H: ON
02H: OFF
34. LONG LIFE Set
Function
The external control equipment sets the PLE, ORBITER, and INVERSE
(inverse of image brightness) of the plasma monitor.
Transmission Data
DFH 80H
60H
6BH
03H
DATA00 DATA01 DATA02 CKS
DATA00: PLE
01H: AUTO
02H: LOCK
DATA01: INVERSE
01H: ON
02H: OFF
03H: WHITE
DATA02: ORBITER (PICTURE SHIFT)
01H: ON
02H: OFF
ACK
The plasma monitor returns the following ACK when setting the PLE,
ORBITER, and INVERSE (inverse of image brightness):
3FH
60H
80H
6BH
00H
CKS