46: +! /# 7)79
46: +! /# 7)79
46: +! /# 7)79
46: +! /# 7)79
READING ACTUAL VALUES
1. IGNITION : Position 1
2. Press the AUTO button
3. Set both temperature selectors to 72 degrees F.
4. Press the REST button for more than 5 seconds.
5. The left display will alternately show the number "1" and the in-car temperature.
6. Press the AUTO button and the next component number and its value will be displayed.
7. Press the REST button to end the test program.
COMPONENT UNDER TEST
Number
Component
01
In-Car Temperature Sensor with Aspirator Blower (B10/4)
02
Outside Temperature Sensor (B14)
03
Left Heater Core Temperature Sensor (B10/1)
04
Right Heater Core Temperature Sensor (B10/1)
05
Evaporator Temperature Sensor (B10/6)
06
Engine Coolant Temperature (ECT) Sensor (A/C) (B1/4)
07
Refrigerant Pressure in Bar
08
Refrigerant Temperature Sensor (B12/1)
10
Blower Control Voltage
11
Emissions (Refrigerant Leak) Sensor (B31)
12
Sun (Excessive Heat) Sensor (B32)
20
Control Current for Auxiliary Fan exp. : 7 = 7 mA
21
Engine RPM. example 00..99 (x100) = 9900
22
Vehicle Speed
23
PIN 58D exp. 99.0 = 99% of Battery Voltage
24
Battery Voltage : 12.8 = 12,8 Volt
40
Software Version Encoded
41
Hardware Version