FAULT DIAGNOSIS
1. IGNITION : Position 1
2. Left Temperature selector wheel : HI
Right Temperature selector wheel : LO
3. Within 20 seconds press the REST and EC buttons simultaneously for more than 5 seconds.
4. The LED in the RECIRCULATE button flashes and "OFF" appears on the display.
5. Press the right AUTO button until all DTC's are displayed and recorded.
6. To erase all codes must be read out. Press both AUTO buttons simultaneously for more than 2 seconds. "d"
will be displayed on the left and "FF" is displayed on the right. The erase can be canceled by pressing the
AUTO button.
7. Reset temperature selector to normal setting.
8. IGNITION : OFF to end the test program.
FAULT CODES - 140 Chassis from 9/95
DTC Readout Description
026
CAN Bus Communication
226
In-Car Air Temperature Sensor (B10/4)
227
Outside Air Temperature Sensor (B10/5) to 1996, (B14) as of 1997
228
Left Heater Core Temperature Sensor (B10/2)
229
Right Heater Core Temperature Sensor (B10/3)
230
Evaporator Temperature Sensor (B10/6)
231
Engine Coolant Temperature Sensor (B11/4)
DFI or IFI models Right Engine Coolant Temperature Sensor (B11/10) to 1996
232
Refrigerant Pressure Sensor (B12)
233
Refrigerant Temperature Sensor (B12/1)
234
Sun Sensor (B32)
235
Emissions (Refrigerant Leak) Sensor (B31)
241
Refrigerant Level
416
Coolant Circulation Pump (A31m1)
417
Left Duovalve (Water Valve) (Y21y1)
418
Right Duovalve (Water Valve) (Y21y2)
419
A/C Compressor Electromagnetic Clutch (A9k1)
420
Closed (Idle) Throttle Speed Increase
421
Pulse Module (N65)
422
Serial Interface Connection (K1) to Instrument Cluster (IC)
423
Switchover Valve Block (Y11)
424
Activated Charcoal Filter Actuator (A32m2) : OPEN
425
Activated Charcoal Filter Actuator (A32m2) : CLOSE
432
Maximum Heat