) 2
) 2
) 2
) 2
107
4:4 +! /# 7)79
4:4 +! /# 7)79
4:4 +! /# 7)79
4:4 +! /# 7)79
READING ACTUAL VALUES
1. IGNITION : Position 1
2. Set temperature selector to 72 degrees F.
3. Press the REST button for more than 6 seconds.
4. The left display will alternately show the number "01" and the in-car temperature.
5. Press the FAN button and the next component number and its value will be displayed.
6. Press the REST button to end the test program.
COMPONENT UNDER TEST
Number
Component
01
In-Car Temperature Sensor with Aspirator Blower (B10/4)
02
Outside Temperature Sensor (B14)
03
Heater Core Temperature Sensor (B10/1)
05
Evaporator Temperature Sensor (B10/6)
06
Engine Coolant Temperature Sensor (ECT) (B11/4)
07
Refrigerant Pressure in Bar
08
Refrigerant Temperature Sensor (B12/1)
09
Not Used
10
Blower Control Voltage
20
Control Current for Auxiliary Fan exp. : 7 = 7 mA
21
Engine RPM. example 00..99 (x100) = 9900
22
Vehicle Speed
23
PIN 58D exp. 99.0 = 99% of Battery Voltage
24
Battery Voltage : 12.8 = 12,8 Volt
40
A/C Controller Software Version Coding
41
A/C Controller Hardware Version
42
Variant code 1
43
Variant code 2
50
Not Used
51
Not Used
52
Not Used
54
ON/OFF A/C Compressor emergency off signal from engine control module.