W i r i n g D i a g r a m :

Factory default setting:

Access mode

Card memory

Transaction memory (MAX 1000 cards)

Master codes (Master password)

(All) Functions of alarm

Door relay time

Key timeout

Awaiting code timeout

Programming mode timeout

Card only (0000)

All Bits

0 pcs

*123456#

Clear the function (00)

3 seconds

5 seconds

5 seconds

25 seconds

I n d i c a t o r s S t a t u s a n d D e f a u l t V a l u e :

Beep & LED indication:

Mode

Signal

Yellow(Flash slowly)

Green On

Red On

Yellow (Flash quickly)

Red(Flash quickly)

1 Beep

2 Beep

1 Beep

2 Beep

Status

Power-on, stand-by

Valid entry, door relay active

Warning, invalid card or code, tamper,alarm relay active

Enter programming mode

Card read, or clear the memory

valid card, keypress, entry program mode

Invalid cards, mistake codes

Valid entry, exit the program mode

Incorrect input or other failed operation

Normal

Programming

Programming

Normal

LED

Beep

S p e c i f i c a t i o n s :

Part No

Connection

Users

Record volumes

Reader application

Keys

Interface

Proximity distance

Indicators

ST-630E

On line

1000

1000

WG26,WG34

12 keys (0-9,*,#)

RS485

10~15cm

125Khz (EM)

Dimension(mm)

Operating voltage

Temperature

Humidity

3 LEDs

114(L)x69.5(W)x10(D)mm

12VDC

-5C~60ºC

5%~95%(Non-condensing)

Proximity frequency

RS 485

White

Green

Locking Device 1

(Fail-Safe)

Blue:N.O.2

Green:Com.2

Yellow:N.C.2

Gray:P2

White:P1

White:B1

Gray:B2

Brown:Reed
Brown:Reed

Blue:LED(Yellow)
Pink:LED(Red)
Green:LED(Green)

Black:V0
Orange:D1
Yellow:D0

Red;+10~14Vdc

RS 485

Auxiliary Reader

Door one

Door two

O p e r a t i o n I n s t r u c t i o n

*XXXXXX#

* #

01*XXXXXXxxxxxx#
02*XXX#
03*XXX#

10*xxxxx*XXXXXXXXXX#

12*xxxxx*XXXXX#

13*xxxxx*XXXXX*N#

Exit program mode

Change default password, press twice new 6-digit codes
Controller station setting (001-254)
Time Delay Setting from 000-250 seconds. 000= toggle mode.
Adding or revise the card No.

Adding the card No. in sequence. xxxxx=the beginning slot position XXXXX=the
quantity of cards. After setting the quantity of cards, read the first card and press “#”
to complete the setting. The access mode is for Card Only after adding the cards.

(p.s.X≦01000)

14*xxxxx*XXXX#

Access mode and clear card setting
xxxxx=The beginning slot position XXXXX=the end slot position
Slot position=00001~01000

N indicates the access mode. 0=Access not allowed, 1=Card Only, 2=Card or Code,
3=Card & Code, 4=Clear card information

Code setting: xxxxx=slot position XXXX= 4-digit code (Position=00001~01000)

15*99#

Clear all cards (Not including master card)

17*XXXXXXXXXX#

Enter card no. to clear the information when forget the slot position. X=10 digit card no.

21*XXX#

Alarm output time setting XXX=000~255 seconds

22*XXX#

The second relay activate time. XXX=000~250 seconds (Second relay for security
system) (000 manual mode) (Default value is 15 seconds)

25*X#

Master cards setting X=(1 or 2) 2 Master card available
Under normal status, proximity the master cards to program mode

26*XXXXX*XXXXX#

Security card arrange setting: XXXXX=00001~01000 (The range of the No. should be

32*X#

Anti-pass-back function X=0 / OFF X=1/ ON

33*X#

Two doors synchronize X=0/OFF X=1/ON Access controller and reader can control
different doors.

34*99#

Clear the function of Anti-pass-back

35*X#

X=1=access record to duty X=0=access record Not to Duty X=default is 0

Enter program mode, enter 6-digit codes (Default 123456)

Slot position=00001~01000 and enter the 10-digit card No.

51*99#

Reset to default, and clean the controller memory to the factory default.

55*99#

Read card once and hear 1 Beep to add new card. Read card twice and h

ear 2 beeps

to clear the card (The default access mode for this instruction is Card Only).

72*XXX#

Door left open alarm time delay setting. XXX=000~255 seconds. The door status reed switch
is required for this function. The second relay active alarm output after the limited time.
(Refer to 21*XXX#)

73*X#

X=1 Enter the emergent code or press 99* with security cards, the relay of the

74*X#

Door left open alarm and force open mode are setting. X=1/ON, X=0/OFF

76*X#

Emergent alarm setting X=1/ON, X=0/OFF

99*

Active the second relay by press the code 99* first, and read the valid card. (without
entering the program mode).

Set the emergent code by entering 6-digit code twice. Enter the code to activate the second
relay. Accompany with the instruction of 22*XXX# to set the second relay active time.

71*XXXXXXxxxxxx#

succeeding without a break in numbering.

controller will be avtivated. X=0/OFF

Blue:N.O.2

Green:Com.2

Yellow:N.C.2

Gray:P2

White:P1

White:B1

Gray:B2

Brown:Reed
Brown:Reed

White

Green

Blue:LED(Yellow)
Pink:LED(Red)
Green:LED(Green)

Black:V0
Orange:D1
Yellow:D0

Red;+10~14Vdc

Relay

Relay

Relay

Relay

Locking Device 1

(Fail-Safe)

Auxiliary Reader

Locking Device 2

(Fail-Secure)

Push Button 2

Push Button 1

Locking Device 2

(Fail-Secure)

Push Button 2

Push Button 1

Door status reed switch contact is (N.
O.) The contact switch is in N.O.(Norm-
al Open) status when the door closes.
The contact switches to N.C. (Normal
Close) when the door opens.

Door status reed switch contact is (N.
O.) The contact switch is in N.O.(Norm-
al Open) status when the door closes.
The contact switches to N.C. (Normal
Close) when the door opens.

Computer

485-TO-USB

485-TO-TCPIP

USB
RJ45

F e a t u r e s :

 Master card and codes
 Auto reset function
 Security system setting / Release
 Synchronize with security system

Entering / Exiting programming mode: Only

proximity, Codes + proximity, Codes or proximity
Door status monitor function
Anti pass back function
Emergent access alarm, time delay alarm and forced door alarm output
Dual relays programmable On / Off or pulsed or latched mode
LED indicator to distinguish the status

Use for all kinds of the electric lock






Use software to connect up to 254 controllers

Copyright © All Rights Reserved.
P-MU-ST-630E Ver. C Publish:2011.06.27

Operation Manual (S1 Mode/On line)

ST-630E Access Control Unit

For DC use only

For AC/DC

The door strike must have a vartistor or a
diode across the door strike terminals to
suppress the back EMF of the strike-failure
to do so will damage the relay contacts and
electronic components.

(Suggested Card: CCTR00-CNPSLD-CN)