Model G0632 (Mfg. 4/12+)

Improper connection of the equipment-grounding
wire can result in a risk of electric shock. The
wire with green insulation (with or without yellow
stripes) is the equipment-grounding wire. If repair
or replacement of the power cord or plug is nec-
essary, do not connect the equipment-grounding
wire to a live (current carrying) terminal.

Check with a qualified electrician or service per-
sonnel if you do not understand these grounding
requirements, or if you are in doubt about whether
the tool is properly grounded. If you ever notice
that a cord or plug is damaged or worn, discon-
nect it from power, and immediately replace it with
a new one.

Extension Cords

We do not recommend using an extension cord
with this machine. If you must use an extension
cord, only use it if absolutely necessary and only
on a temporary basis.

Extension cords cause voltage drop, which may
damage electrical components and shorten motor
life. Voltage drop increases as the extension cord
size gets longer and the gauge size gets smaller
(higher gauge numbers indicate smaller sizes).

Any extension cord used with this machine must
contain a ground wire, match the required plug
and receptacle, and meet the following require-
ments:

Minimum Gauge Size ...........................16 AWG

Maximum Length (Shorter is Better).......50 ft.

Grounding Requirements

This machine MUST be grounded. In the event
of certain malfunctions or breakdowns, grounding
reduces the risk of electric shock by providing a
path of least resistance for electric current.

Figure 4. Typical 6-15 plug and receptacle.

Grounding Prong

Current Carrying Prongs

6-15 PLUG

GROUNDED

6-15 RECEPTACLE

For 220V operation: The plug specified under
“Circuit Requirements for 220V” on the previous
page has a grounding prong that must be attached
to the equipment-grounding wire on the included
power cord. The plug must only be inserted into
a matching receptacle (see following figure) that
is properly installed and grounded in accordance
with all local codes and ordinances.

Serious injury could occur if you connect

the machine to power before completing the

setup process. DO NOT connect to power

until instructed later in this manual.

No adapter should be used with the

required plug. If the plug does not fit the

available receptacle, or the machine must

be reconnected for use on a different type

of circuit, the reconnection must be made

by a qualified electrician and comply with all

local codes and ordinances.