FUJITSU SPARC ENTERPRISE M4000 User Manual
Page 46

cfgdevice(8)
28
XSCF Reference Manual • Last Revised June 2007
The current status of the drive that is displayed with this command includes the
following types of status information:
The cfgdevice(8) command is valid only for high-end server.
Privileges
You must have one of the following privileges to run this command:
■
For connection and disconnection:
platadm
, fieldeng
■
For displaying the status:
platadm
, fieldeng
Refer to setprivileges(8) for more information.
port_no
Port number of the port where the IOUA is installed and that
can be connected to the DVD drive/tape drive unit. It is
displayed in the "IOU number-PCI slot number" format.
IOU/SAS-status
Connection status between IOUA and built-in switching unit.
It is changed by specifying "attach" or "detach."
■
enable/disable
: Setting status of the cfgdeive(8)
command
enable
: Connected with "-c attach."
disable
: Not connected.
■
up/down
: Logical connection between IOUA and built-in
switching unit.
up
: Connected.
down
: Not connected.
SAS-status
Connection status between I/O unit and the system.
■
enable/disable
: Connection setting between I/O unit
and the system. When starting a domain with no I/O unit,
the "disable" may be displayed.
enable
: Yes
disable
: No
■
up/down
: Logical connection between I/O unit and the
system.
up
: Connected.
down
: Not connected.