Showstatus – FUJITSU SPARC ENTERPRISE M4000 User Manual
Page 399

showstatus(8)
System Administration
467
NAME
showstatus - display the degraded Field Replaceable Units (FRUs)
SYNOPSIS
showstatus
[-M]
showstatus -h
DESCRIPTION
showstatus
(8) command displays information about degraded units that are
among the FRUs composing the system.
Privileges
You must have one of the following privileges to run this command:
useradm
, platadm, platop, domainadm, domainmgr, domainop, fieldeng
Refer to setprivileges(8) for more information.
OPTIONS
The following options are supported:.
EXTENDED
DESCRIPTION
Displays the information concerning the units failed or degraded and the units on
the next upper layer, among the FRUs composing the system. An asterisk (*)
indicating abnormal unit is displayed along with any of the following the
"Status:":
EXAMPLES
EXAMPLE 1
Displays the degraded units. In this example, a CPU module and memory
module in a CPU memory unit are degraded because of an error.
-h
Displays usage statement. When used with other options or
operands, an error occurs.
-M
Displays text by page. This option provides a function that is
the same as that of the more command.
Status
Description
Faulted
The component is faulty and is not operating.
Degraded
The component is operating. However, either an error has been
detected or the component is faulty. As a result, the component
might be operating with reduced functionality or performance.
Deconfigured
As a result of another component's faulted or degraded status,
the component is not operating. (The component itself is not
faulted or degraded.)
Maintenance
The component is under maintenance. A deletefru(8),
replacefru
(8), or addfru(8) operation is currently underway.
XSCF>
showstatus
CMU#0;
* CPUM#0-CHIP#0 Status:Faulted;
* MEM#00A Status:Faulted;