Finalizing the Installation

(for qualified installers only)

39

© Travis Industries

4090102

100-01212_000

Log Set Installation

Ember Placement

Place the embers along the firebox floor and burner to help conceal the burner. Make sure none of
the embers are directly over the burner holes. See the photo below.

Rock Wool Placement

The rock wool must be pulled apart and made into a thin gauze prior to placing over the burner.
See the illustration below for details.

NOTE: Propane (LP) units use a lighter amount of rock wool than natural gas units.

Place small pieces of rock wool next to the burner holes in

visible locations. Place the rock wool sparingly so it does

not cover large areas of the burner.

WARNING: If the rock wool is too thick or placed so it

obstructs the flow of gas, sooting will occur.

Preparing the Rock Wool:

The rock wool comes in one

clump. Tear off “dime” sized

clumps and flatten. Then pull on

the wool to create gauze-like

pieces. The wool glows best

when very thin and porous.

Note how the embers do not
cover any burner holes. Place
the embers around the burner
to create a realistic effect.