Installation, Mantel requirements, For qualified installers only) – FireplaceXtrordinair Revolution 36CF User Manual

Page 35: See through pier

background image

Installation

(for qualified installers only)

35

© Travis Industries

4090102

100-01212_000

Mantel Requirements

The mantel (combustible or non-combustible) must be a minimum 49-1/2” above the base of
the fireplace (see Figure 24).

The maximum mantel depth is 12” (measured from the face).

Max. 12”

Base of the Fireplace

Min. 49-1/2”

Mantel

(combustible or non-combustible)

Combustible mantel columns (legs) that
protrude less than 4” (measured from the
fiber board) must be 2” from the glass frame.
If the mantel columns protrude more than 4”,
they must meet the sidewall clearance (12”
from the glass frame).

Non-combustible mantel columns do not
have a minimum clearance.

Base of the Fireplace

Mantel

(combustible or non-combustible)

Max. 12”

Max. 12”

SEE THROUGH

PIER

Min. 49-1/2”

Figure 24