4.4.80.
Map Descriptor Example 77 - set stop time = month/day hour:minute
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Data_Array_Name,
Data_Array_Offset,
Function, Node_Name,
SysPlus_Cmd,
Par_Data_Array_Name,
Par_Data_Array_Offset,
Length
Set_Stop_Time,
Par_Bit_Triggers,
2,
awt,
SYSPLUS_01,
Set_Stop_Time,
Set_Stop_Time,
0,
1
This command is used by first writing the parameter data and then triggering the command by writing any value to Data_Array_Name
at Data_Array_Offset.
Parameter data setup:
Offset from par_data_array_offset Description
0
Month
1
Day
2
Hour
3
Minute
4.4.81.
Map Descriptor Example 78 - set date = month / day / year
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Data_Array_Name,
Data_Array_Offset,
Function, Node_Name,
SysPlus_Cmd,
Par_Data_Array_Name,
Par_Data_Array_Offset,
Length
Set_Date,
Par_Bit_Triggers,
3,
awt,
SYSPLUS_01,
Set_Date,
Set_Date,
0,
1
This command is used by first writing the parameter data and then triggering the command by writing any value to Data_Array_Name
at Data_Array_Offset.
Parameter data setup:
Offset from par_data_array_offset Description
0
Month
1
Day
2
Year