FieldServer Envirotronics SystemsPlus FS-8700-88 User Manual
Page 27
FS-8700-88 Envirotronics SystemsPlus
Page 27 of 49
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldServer.com
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]
4.4.63.
Map Descriptor Example 60 - edit set engineering min. = value
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Data_Array_Name,
Data_Array_Offset,
Function,
Node_Name,
SysPlus_Cmd,
Length
Ed_Set_Eng_Min,
Ed_Set_Eng_Min,
0,
wrbx,
SYSPLUS_01,
Ed_Set_Eng_Min,
1
A value of value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.64.
Map Descriptor Example 61 - edit set engineering max. = value
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Data_Array_Name,
Data_Array_Offset,
Function,
Node_Name,
SysPlus_Cmd,
Length
Ed_Set_Eng_Max,
Ed_Set_Eng_Max,
0,
wrbx,
SYSPLUS_01,
Ed_Set_Eng_Max,
1
A value of value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.65.
Map Descriptor Example 62 - edit set analog address = number
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Data_Array_Name,
Data_Array_Offset,
Function,
Node_Name,
SysPlus_Cmd,
Length
Ed_Set_Ana_Addr,
Ed_Set_Ana_Addr,
0,
wrbx,
SYSPLUS_01,
Ed_Set_Ana_Addr,
1
A value of number must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.66.
Map Descriptor Example 63 - edit set units = number
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Data_Array_Name,
Data_Array_Offset,
Function,
Node_Name,
SysPlus_Cmd,
Length
Ed_Set_Units,
Ed_Set_Units,
0,
wrbx,
SYSPLUS_01,
Ed_Set_Units,
1
A value of number must be written to Data_Array_Name at Data_Array_Offset to trigger this command.