4.4.59.
Map Descriptor Example 56 - edit set next = next_step_num
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Data_Array_Name,
Data_Array_Offset,
Function,
Node_Name,
SysPlus_Cmd,
Length
Ed_Set_Next,
Ed_Next,
0,
wrbx,
SYSPLUS_01,
Ed_Set_Next,
1
A value of next_step_num must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.60.
Map Descriptor Example 57 - edit set analog min. = value
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Data_Array_Name,
Data_Array_Offset,
Function,
Node_Name,
SysPlus_Cmd,
Length
Ed_Set_Ana_Min,
Ed_Set_Ana_Min,
0,
wrbx,
SYSPLUS_01,
Ed_Set_Ana_Min,
1
A value of value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.61.
Map Descriptor Example 58 - edit set analog max. = value
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Data_Array_Name,
Data_Array_Offset,
Function,
Node_Name,
SysPlus_Cmd,
Length
Ed_Set_Ana_Max,
Ed_Set_Ana_Max,
0,
wrbx,
SYSPLUS_01,
Ed_Set_Ana_Max,
1
A value of value must be written to Data_Array_Name at Data_Array_Offset to trigger this command.
4.4.62.
Map Descriptor Example 59 - edit set analog type = number
// Client Side Mao Descriptors
Map Descriptor
Map_Descriptor_Name,
Data_Array_Name,
Data_Array_Offset,
Function,
Node_Name,
SysPlus_Cmd,
Length
Ed_Set_Ana_Type,
Ed_Set_Ana_Type,
0,
wrbx,
SYSPLUS_01,
Ed_Set_Ana_Type,
1
A value of number must be written to Data_Array_Name at Data_Array_Offset to trigger this command.