beautypg.com

Requirements, Requirements at the managed server, 1 requirements – FUJITSU Primergy ServerView Suite ServerView Remote Management Frontend V4.90 User Manual

Page 16

background image

16

ServerView Remote Management Frontend

Requirements

Starting the Remote Management Frontend

3.1

Requirements

Before you can start the Remote Management Frontend and establish a
connection to the managed server, a number of requirements must fulfilled both
at the managed server and at the remote workstation.

3.1.1

Requirements at the managed server

Depending on whether the Remote Management Frontend accesses the
managed server via an iRMC/ iRMC S2, an RSB/ RSB S2/ RSB S2 LP, a BMC
or a RemoteView Management Blade, the following requirements must be
fulfilled at the managed server:

iRMC/ iRMC S2

Both the iRMC/ iRMC S2's LAN interface and text console redirection (via
Serial Over LAN) must be configured.

I

Text console redirection via Serial over LAN (SOL) assumes that the
operating system and/or the BIOS use serial port 1 (COM1) for text
console redirection.

For detailed information, see the manuals “iRMC - integrated Remote
Management Controller” and “iRMC S2 - integrated Remote Management
Controller”.

RSB S2/ RSB S2 LP (3HU)

Access via the Remote Management Frontend to an
RSB S2/ RSB S2 LP/ RSB S2 LP (3HU) is only possible if the
RSB S2/ RSB S2 LP/ RSB S2 LP (3HU) is operated with firmware version
*29 or higher.