FUJITSU Primergy ServerView Suite ServerView Remote Management Frontend V4.90 User Manual

Page 12

background image

12

ServerView Remote Management Frontend

Configuration

Installation and configuration

SSH access to the iRMC/ iRMC S2:

In the

ServerView [server-name]

window for PRIMERGY servers with

iRMC/ iRMC S2, the

iRMC SSH

button for SSH access to the

iRMC/ iRMC S2 is displayed (see

figure 5 on page 22

).

Default value: The

iRMC SSH

button is displayed.

Console redirection (SOL) and power management for PRIMERGY
servers with iRMC/ iRMC S2:

The corresponding button (

iRMC Power Management

) is displayed in the

ServerView [server-name]

window (see

figure 5 on page 22

).

Default value: The

iRMC Power Management

button for console redirection

(SOL) and power management is not displayed.

Configuring settings in the “Features” folder

You can activate or deactivate the individual features (multisession support,
display of certain buttons) by creating or deleting the corresponding text files in
the

Features

folder. The content of the text files is irrelevant, i.e. the files can be

empty.

The following fixed names must be used for the text files:

MultiSessionBMC

Multisession support for BMC/ iRMC/ iRMC S2 power management and
console redirection is activated.

SSHiRMC

The button for SSH access to iRMC/ iRMC S2 is displayed for
PRIMERGY servers with iRMC/ iRMC S2.

SOLiRMC

The button for console redirection (SOL) and power management is
displayed for PRIMERGY servers with iRMC/ iRMC S2.

I

Please note:

The file names are not case-sensitive.

The file names must not have any name suffix (

.txt

).